Keep walls dry.
Lets buildings breathe.
Complies with AS/NZS 4200.1
Sizes
Tested. Certified. Trusted
| PROPERTY | TEST METHOD | REQUIREMENT CLASS 4 (MINIMUM) |
RESULT |
|---|---|---|---|
|
|
ASTM E96 (Water Method) |
≥ 1.1403 μg/N·s (Class 4 minimum) |
WVTR 567.6 g/m²/24 hr Permeance |
|
Vapour Permeability |
AS/NZS 4200.1 (Clause 5.4) |
≥ 2.0 g/m²/24 hr | 3.6 g/m²/24 hr PASS |
|
Water Resistance |
AS/NZS 4200.1 (Clause 5.3) |
≥ 300 mm | > 400 mm PASS |
|
|
AS/NZS 4200.1 (Clause 5.2) |
≤ 0.02 L/s/m² at 75 Pa |
0.01 L/s/m² PASS |
|
|
AS/NZS 4200.1 (Clause 5.5) |
Pass at 2500 Pa | > 2500 Pa PASS |
|
Water Penetration |
AS/NZS 4200.1 (Clause 5.1) |
No penetration | No penetration PASS |
|
Flammability Index |
AS 1530.2 | ≤ 5 | 1 PASS |